Phidix Motion Controls (Shanghai) Co., Ltd.

Phidix Optical Instruments Bring you premium products, services & solutions.

Manufacturer from China
Active Member
4 Years
Home / Products / Lab Biological Microscope /

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Contact Now
Phidix Motion Controls (Shanghai) Co., Ltd.
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrJohnny Zhang
Contact Now

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Ask Latest Price
Video Channel
Brand Name :Phidix
Model Number :M12111
Certification :IATF16949,CE
Place of Origin :China
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union
Supply Ability :1000 PCS/Month
Delivery Time :15-20 Work Days
Packaging Details :1 PC/Carton
Color :White
Customization :OEM, ODM
Packing :1 PC/Carton
Warranty :1 year
Drawtube :Trinocular
Theory :Biological Microscope
Lead-time :15-20 Work Days
Eyepiece :WF10X
Optical System :Infinity Achromatic
Objective :10X/20X/40X/100X
Observation :LED Fluorescence
Illumination :100W mercury lamp
Application :Hospital, Education, Industry, Study Institution
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

LED Fluorescent Trinocular Biological Microscope For Medical Lab Para Celular 180 X 155mm White

M12111 LED Fluorescent Trinocular Biological Microscope For Medical Lab Para Celular 180 X 155mm White. M12111 biological microscope is designed to present a safe, comfortable and efficiency observation experience for users. With perfectly performed structure, high-definition optical image and simple operating system, M12111 realizes professional analysis, and meets all the needs of research in scientific, medical and other fields.

Features:

- Modularization function design so that update system expediently

- Bright Field Observation Available

- Ideal ergonomic design is adopted in this unit and has easier operation and wider space

- Excellent optical system can obtain excellent optical performance.

- The large-mobile range mechanical stage is adapted to observe big size specimen or quick check.

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Large stage with adjustment in either hand

■ In order to correct the shortcoming of horizon guide rail, new stage is designed with double-way linear driving mechanism. This change protects the stage from overload at the end of both rails, improves the rigidity and performance of the stage.

■ The handle of the stage can be set at each side based on users’ preference. The X, Y biaxial adjustments are designed with low position for comfortable operation.

■ Two slices can be hold on the stage by using damping-type double clips, easy for comparative study. Moving range: 80mm X55mm; precision: 0.1mm.

■ Processed with special craft, the surface of the stage is anticorrosive and anti-friction. The platform with an arc transition design reduces the stress concentration and damage from impact.

■ Light barrier, which can effectively reduce the stray light, improves the image contrast in fluorescence observation.

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Modular frame, improving the system compatibility

M12111 with modularization design, separated cross arm and main body, improves the system compatibility of biological and fluorescence frame.

Highly sensitive coaxial coarse and fine adjustment

Coaxial adjustment adopts double-stage driving, with adjustable tension tightness and upper limit stop, coarse range is 25mm and fine precision is 1μm. Not only accurately focus but also precision measurement is available.

Viewing head with multi-splitting ratio

M12111 viewing head is designed of multiple options for splitting ratio with wide beam imaging system, 26.5mm super wide field of view is available.

Trinocular head with inverted image, splitting ratio Binocular: Trinocular=100:0 or 20:80 or 0:100. Except for concentrating 100% light to eyepiece tube or camera tube, there is another option with 20% light to eyepiece tube and 80% to camera tube, so that eyepiece observation and image output can be available at the same time.

Trinocular head with erect image, splitting ratio Binocular:Trinocular= 100:0 or 0:100. The moving

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Multi-functional condenser

Disc condenser with 3 small holds and 5 big holds to attach different accessories for different observation requirement, such as bright field, dark field, phase contrast, DIC and polarizing. Fast switch and easy operation is

available to improve the working efficiency.

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Multifunctional reflection illumination

In M12111 reflection fluorescent illumination, maximum 6 fluorescence filters can be assembled at the same time. Filters are placed in a rotary table for convenient switch. High precision and stable rotary table and high-performance imported filter ensures a drift-free image.

■ There is a light shutter in front of the reflected illuminator. It is used to shut the fluorescent light to prevent fluorescence quenching of the slice.

■ The light barrier can protect users from the harm of UV light.

■ The use of ND attenuation filter, or aperture and field diaphragm rod can efficiently reduce the intensity of exciting light to protect the slice.

■ After replacing the lamp, the centering objective helps users in adjusting the filament center to make sure a sufficient and uniform fluorescent illumination.

Power control system for mercury lamp

New digital power control system with operating time and current value, clearly shows the working state of the mercury lamp. Two power supply systems, providing multiple choices of high quality illumination. New developed 100W EHV DC mercury lamp house with improved thermal cycle greatly reduces the surface temperature of the lamp house and avoids the scald risk during operation. The filament center is easily adjustable. 75W xenon lamp for option.

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Compound Eye Illumination System

M12111 innovatively adopts the compound eye illumination system to improve the contrast ratio and effectively improve the illumination uniformity of the specimen surface. The brightness of the entire field of view is uniform, even at the edge of the field of view can be achieved uniform and bright background brightness under any magnification.

Upgraded mechanical stage

■ M12111LED double-layer mechanical stage with X-axis & Y-axis rackless. X-axis rackless adopt the overload protection and avoid the potential hazard caused by moving rack.

■ Under ultra-low hand position operation mode, no need to worry about soreness caused by prolonged operation. Users can put their elbows on workbench completely during the focusing process.

Comprehensively Improve the Convenience of Use

■ Non swing out Abbe condenser avoids repeated operation during objectives switching and improves work efficiency;The NA is increased from NA0.9 to NA1.1, which fully meets the use of 4x-100x observation.

■ The main power switch is set on the side of the M12111LED microscope body, and the one button switch is accessible; M12111LED is reduced the depth of the whole machine. Placing M12111LED on the standard 600mm wide desktop,the eyepiece and observation head will not exceed the edge of the desktop, so as to avoid personnel walking and colliding with the microscope.

■ M12111LED adopts sextuple nosepiece, which can record the illumination brightness of each objective lens.

The user can freely adjust the light source brightness of each objective lens, and the system automatically records the brightness. There is no need to adjust back and forth with the switching of magnification, which not only improves the work efficiency, but also reduces visual fatigue.

Wide Range of Applications

M12111LED can be widely used in basic scientific research, teaching and pathological analysis to meet the needs of biology, medicine and other laboratories for cell tissue observation.

Professional software for fluorescence analysis, with powerful function and easy operation.


CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Camera Specification:

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

M12111 Specification:

Items Specification M12111
Optical system Infinity color corrected optical system
Viewing head Inverted image, 30° inclined gemel trinocular head, interpupillary distance: 50mm~76mm; splitting ratio R:T=100:0 or 20:80 or 0:100
Erect image, 30° inclined gemel trinocular head, interpupillary distance: 50mm~76mm; splitting ratio R: T=100:0 or 0:100
Inverted image, 5~35 degree tilting head, interpupillary distance: 50mm~76mm; splitting ratio R:T=50:50 or 100:0 or 0:100
Eyepiece High eyepoint wide field plan eyepiece PL10X25mm, diopter adjustable
High eyepoint wide field plan eyepiece PL10X25mm, with reticle, diopter adjustable
High eyepoint wide field plan eyepiece PL10X26.5mm, diopter adjustable
Objective Plan semi-apochromatic objectives (4X/10X/20X/40X/100X)
Plan apochromatic objectives (2X/4X/10X/20X/40X/60X/100X)
Plan apochromatic phase contrast objectives (4X/10X/20X)
Nosepiece (with DIC slot) Quintuple nosepiece
Sextuple nosepiece, is able to be updated to memory the brightness
Septuple nosepiece
Frame

Biological frame (transmitted), low-position coaxial coarse and fine adjustment, coarse adjustment distance: 25mm; fine precision: 0.001mm. With coarse adjustment stop and tightness adjustment.Built-in 100-240V_AC50/60Hz wide voltage

transformer, intensity adjustable by digital set and reset; built-in transmitted filters LBD/ND6/ND25).

Fluorescence frame (transmitted), low-position coaxial coarse and fine adjustment, coarse adjustment distance: 25mm; fine precision: 0.001mm. With coarse adjustment stop and tightness adjustment.Built-in 100-240V_AC50/60Hz wide voltage

transformer, intensity adjustable by digital set and reset; built-in transmitted filters LBD/ND6/ND25).

Condenser Swing-out type achromatic condenser (N.A.0.9)
Multi-functional condenser with built-in polarizer, is available to attach phase contrast/dark field/DIC accessory
Reflected fluorescence illuminator Sextuple reflected fluorescence illuminator with iris field diaphragm and aperture diaphragm, central adjustable; with filter slot and polarizing slot; with fluorescence filters (UV/B/G for option).
100W mercury lamp house, filament center and focus adjustable; with reflected mirror, mirror center and focus adjustable.
Imported OSRAM 100W mercury lamp.
Transmitted illuminator 12V/100W halogen lamp house for transmitted light, center pre-set, intensity adjustable

Other accessories

Camera adapter:0.35/ 0.5X/0.65X/1X focusing C-mount;
Cooling CCD camera, Centering objective for fluorescence observation;
Professional software for fluorescence analysis;
High precision micrometer, scale value 0.01mm.

Note: ● means standard, ○ means optional

M12111LED Optical Biological Microscope Size (mm)

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

M12111 Series Microscope General Layout Diagram

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

CMOS CCD 20MP Biology Lab Microscope AOP Objective Research Microscope

Inquiry Cart 0